5.
Install the silencer screen (21) and the silencer cap
(20).
6.
Fit the cover and tighten the screws
Air filter (Fig. 6)
If the engine operates frequently in dusty or other se-
vere circumstances, clean the air filter element every
10 hours. If necessary, change the air filter element
every 25 hours. Also refer to the service information.
Clean the air filter (19) regularly, and if necessary ex-
change it.
• Open the air filter cover (18).
• Remove the filter element (19).
• When cleaning the element do not use any strong
cleaners or petrol.
• Clean the element by tapping it on a flat surface. If it
is very dirty wash with soapy water, rinse with clean
water and leave to dry.
• Put it back together in the opposite order.
Spark plug (Fig. 4)
Check the spark plug after the first 20 hours of use for
dirt and if necessary clean it with a copper wire brush.
Then service the spark plug after every 50 hours of
use.
• Remove the cover.
• Remove the spark plug connector (16) with a turning
movement.
• Remove the spark plug with the spark plug socket
(E) included.
• Put it back together in the opposite order.
Petrol filter (Fig 8+9)
Note: The petrol filter (22) is a filter bowl located directly
under the petrol cap (2) , filtering any petrol added.
1.
Turn the on /o ff switch (10) to the "OFF" position.
2.
Open the petrol cap (2)
3.
Remove the petrol filter (22) and clean in a non-
flammable solvent or solvent with a high flash
point.
4.
Reinsert petrol filter (22).
5.
Close the petrol cap (2).
Changing the oil (Fig. 5)
If the petrol engine operates frequently under high tem-
peratures or high loads, change the oil every 25 hours.
24 | GB
Changing the oil should take place when the engine
is warm.
WARNING! Drain fuel before replacing the oil.
Only use engine oil (15W-40).
• Always set up the device on a level and stable sur-
face. Do not operate the generator on forest soil,
which radiates heat during operation and in the
cooling phase and can ignite flammable materials!
• Remove the screws and the cover (5).
• Open the oil filler cap (17) and drain the warm engine
oil into a container by tilting the generator.
• Pour in engine oil (approx. 0.28 litres).
• Close the cover (5) and tighten the screws.
Low oil switch off
The low oil switch-off responds, if there is not enough
engine oil. The oil check bulb (12) starts to flash when
there is insufficient oil in the motor. The check bulb be-
gins to flash when the oil amount has gone below the
safe level. The engine will turn off independently after
a short time. Restart is possible only after pouring in
more engine oil.

10. Storage

Preparation for storage
• Empty the petrol tank with a petrol suction pump. Re-
move fuel filter and drain the carburettor. Loosen the
screw on the lower side of the carburettor and drain
the petrol into a receptacle provided for this purpose.
Warning notice: Do not remove fuel in closed
rooms, close to fire or whilst smoking. Vapours can
cause explosions or fires.
• Start the engine and leave it running until the rest of
the petrol has been used up.
• Store fuel in tanks specifically designed for this pur-
pose.
• Change the oil after each season. To do this, remove
the old oil from the warm engine and refill with new
oil.
• Remove the spark plug. Fill about 20 ml of oil into the
cylinder using an oil can.
• Slowly pull the express start so that the oil protects
the cylinder from the inside.
• Screw the spark plug back in
• Store the device in a well ventilated place or area.