8
BEDIENUNG
Process Data In (PDI)
Tabelle 13: PDI: Read EPC; Index: 0x78, Subindex: 0, Value: 0
Bitoffset
255
Byte 0
Request
Executed
Type [Subindex] Boolean [6] Boolean [5] Unsigned Integer 3 [4]
Bitoffset
Byte 1
RSSI / 2nd error code
Type [Subindex] Integer 8 [7]
Bitoffset
Byte 2
Power / 1st error code
Type [Subindex] Unsigned Integer 8 [8]
Bitoffset
Byte 3
Length
Type [Subindex] Unsigned Integer 8 [9]
Bitoffset
Byte 4 ... 5
PC Word
Type [Subindex] Unsigned Integer 8 [10 ... 11]
Bitoffset
Byte 6 ... 31
EPC
Type [Subindex] Unsigned Integer 8 [12 ... 37]
Tabelle 14: PDI: Read EPC, Detailbeschreibung
Name
Request Executed
Trigger
Operation Code
Error Flag
Tag Present
Device Status
Error code
RSSI
Power
Length
42
B E T R I E B S A N L E I T U N G | RFU61x IO-Link
254
Trigger
Operation Code
Value
0 --> 1
1 --> 0
0 / 1
1
001
0 / 1
0 / 1
0 / 1
siehe „Error codes", Seite 60
RSSI Signalpegel des Transponders [dBm]
Verwendete Sendeleistung [dBm]
Länge der gelesenen EPC-Daten
251-253
Error Flag
Boolean [3] Boolean [2] Boolean [1]
Beschreibung
Neue Daten verfügbar
Keine neuen Daten verfügbar
Automatische kontinuierliche Triggerung (immer eingeschal‐
tet)
Lese EPC (nicht änderbar)
0: kein Fehler
1: Fehler (siehe Error Code (Byte 1+2))
0: kein Tag erkannt
1: Tag erkannt
0: Gerät nicht bereit
1: Gerät bereit
1)
250
249
248
Tag Present Device Sta‐
tus
240-247
232-239
224-231
208-223
0-207
8026853/1HLX/2022-09-30 | SICK