Operation

10.1 Requirements for operation

External combustion air supply
Every combustion requires oxygen. This is drawn from the environment of the heating appliance.
In modern buildings the outside covering is very thick. Therefore there is an insufficient flow of fresh
combustion air. In such cases the supply of external combustion air is necessary. This is required even
with the use of aeration and ventilation systems in the home.
NOTICE
The combustion air connection is marked on the rear of the appliance with a supply air symbol
Fig. 42: Combustion air supply connection
Connection to the chimney
The information in this manual is of a general nature. National and European standards, local and
building regulations, together with fire regulations must also be complied with.
The stove must be connected to a chimney approved by the chimney sweep. Penetration of condensa-
tion into the stove must be avoided.
NOTICE
The flue pipe connection is marked on the rear of the appliance with an exhaust gas symbol
The flue pipe connection must be executed in accordance with the technical data sheet.
• The chimney must be designed in accordance with the stove's technical data (see Technical data).
• The horizontal length of the exhaust pipe must not exceed 2.5 m.
EN
On some appliance models, connection via the floor is also
possible.
A pipe or hose of Ø 125 mm must be used for connecting
the external combustion air supply. The length of the pipe
or hose should be no longer than 5 m. This supply line must
have no more than three bends.
Provision must be made for adequate provision of combus-
tion air and air for ventilation. The air grille for providing
combustion air must not be accidentally disabled while the
heating appliance is operating.
Lack of combustion air causes poor combustion, and in-
creased soot formation and volume of ash.