Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Modes; Pellet Operation; Log Operation - Austroflamm Scotty Duo Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10 | Operation

10.3 Operating modes

10.3.1 Pellet operation

Fig. 45: Automatic ignition
Fig. 46: Pellet operation

10.3.2 Log operation

Log heat output setting - quantity of wood
The heat output setting affects the automatic combustion. In order to guarantee correct combustion,
the output must be chosen to match the inserted quantity of wood.
Output level 1: Conservation of embers (no combustion of log)
Output level 2: approx. 1.0 kg wood
Output level 3: approx. 1.4 kg wood
Output level 4: approx. 1.7 kg wood
Output level 5: approx. 2.0 kg wood
38
EN
Automatic ignition
The stove can be started with the start/stop button on the
status display or heat output display.
As an option it can be started via IR remote control or via
the app. Ignition of the pellets is fully automatic and takes
place in several phases. These phases are shown on the dis-
play (riddling grate placement - combustion pot filling - ig-
nition phase 1 - firebox temperature build-up - ignition
phase 2 - ignition control - ignition phase 3 - release and
control by user - full fire phase).
Ignition is cancelled by pressing the start/stop button dur-
ing the ignition phase. An "E102" error message appears if
ignition is cancelled.
Pellet operation
In pellet operation, pellet quantity and combustion air are
supplied according to the set heat output.
The desired room temperature must be set in the room
temperature display. If this is reached, the stove automatic-
ally regulates to the lowest output level or switches OFF if
the ECO function is enabled (see Settings/ECO mode).
Pressing the stop button switches the stove into burnout
phase.
The current room temperature is measured using a cable-
attached temperature sensor on the back of the appliance.
In pellet operation, a fluctuating chimney draught or in-
creasing contamination of the exhaust gas pipes is automat-
ically balanced by the exhaust gas fan.
If during the pellet operation the door is opened and
closed again, the stove switches into hybrid start.