Herunterladen Inhalt Inhalt Diese Seite drucken

Mie 4-02 And Mie 8-02 (Dvb-T2) - axing MIE 8-00 Betriebsanleitung

Chp - compact high performance kopfstellen
Vorschau ausblenden Andere Handbücher für MIE 8-00:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation instructions | MIE 8-00 | MIE 16-00 | MIE 32-00 | MIE 4-02 | MIE 8-02 | MIE 3-02 | MIE 6-02
3.5.3.

MIE 4-02 and MIE 8-02 (DVB-T2)

Configuration of the modulators
Select a
modulator
 Select a modulator from MODULATOR 1 to MODULATOR 4 on the left.
 Make the required changes.
 Click SAVE for each modulator.
Only then the changes will be saved, otherwise the changes will be lost.
Parameters:
Common Output level
Norm
Output Channel
DVB-T2 Constallation
FEC Coderate
Page 38 of 68
The Common Output Level option include a general attenuation of all modulator outputs. The
highest output level is reached with a setting of 20 dB, the lowest level with a setting of 0 dB.
In this selection field, you can set the norm for the output channel spacing.
Note: Changing the norm works now according to following rules:
CCIR-->Australia : all modulators forced to 7MHz
Australia-->CCIR : all modulators forced to 8MHz, however with following exception: low
channels S2-S20 are 7MHz only, so those remain in 7MHz
Each of the modulators can be set to any output channel. No output channel may be selected
more than once!
The modulation can be adjusted to the following methods:
QPSK (2 bit) – small data rate – very robust signal.
QAM 16 (4 bit) - low data rate.
QAM 64 (6 bit) - middle data rate.
QAM 256 (8 bit) - high data rate.
Thanks to the error correction, errors resulting from high-disturbed transmission routes can be
balanced by restoring data. The data required to restore the signal are included in the transmitted
FEC bits.
Changing the FEC factor modifies the part of the FEC data in relation to the application data (1/2,
3/5, 2/3, 3/4, 4/5, 5/6). A higher part of FEC data means an higher transmission redundancy. But
this reduces the bandwidth for the useful data too.
FEC 1/2 - small data rate - strong protection against errors.
FEC 5/6 - high data rate - weak protection against errors.
BA_MIE.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2022-05-31