4.13.3. Read NIT

Under STEP 1: READ NIT (DVB-C) the devices in the network are displayed.
 Select the devices from which the NIT is to be read out.
The device you are currently configuring (This device) is always selected.
 Click on READ NIT.
The data of the devices are read in and listed under STEP 2: VERIFY NIT.
Note: If necessary, you must reset the NIT before importing (see „Reset the NIT" on page 62).

4.13.4. NIT Check

Note: If the NIT is edited, the headend automatically switches to cross-multiplex mode.
Values that overlap are displayed in red. These errors must be cleaned up before uploading.
Notes:
Different TS-IDs must always be assigned
The ON-ID must be the same for all headends

4.13.5. Edit NIT

 Click the pen symbol next to a line.
The fields can be edited.
 Click on the plus sign in the column header.
An additional line is inserted.
Enter plausible data in the fields, matching the other values.