Operation instructions | MIE 8-00 | MIE 16-00 | MIE 32-00 | MIE 4-02 | MIE 8-02 | MIE 3-02 | MIE 6-02
Power failure: The internal voltage is too low (<11.0 V).
Temp to high: The temperature of the processor rises too high ( >90°C). At this temperature, the unit will still operate
normally, but probably there are ventilation problems and the temperature will continue to rise. Selecting this condition
allows an immediate smooth transition before the temperature rises so high that the processor may stop working.
No connection (>120s): The backup device is not able to connect to the monitored device via the Control port within 120 s.
Note: This option requires special caution! For example, a loose Ethernet cable can separate the two devices, which can
lead to an unwanted replacement, and both devices send HF output signals simultaneously.
Switching to the backup device is normally done after the device has been in an error state for more than 60 seconds
(exception for the No connection error (>120s)).
 Select one or more conditions.
 Then click SAVE CHANGES.

4.13. Network Information Table (NIT)

The NIT Network Information Table transmits a series of parameters in the digital data stream that are necessary for a scan of the
receivers. The specific parameters within the NIT, such as ONID – Original Network ID and TS-ID – Transmitting Subscriber ID, can
each be configured. In addition, transmission parameters can be added and changed manually from other headends. This makes it
easy to manage the receivers's channels at the headend. The channel searching procedure will be faster and more reliable.

4.13.1. Start NIT Configuration

 Click on NIT CONFIGURATION to open the settings dialog.

4.13.2. Select type

 Select Auto.
An NIT is created that contains all channels (from 114 MHz to 1002 MHz).
The unoccupied channels contain only the most important parameters such as symbol rate and modulation.
 Select Off.
There is no NIT created and therefore no LCN output.
 Select Manual.
The input fields for reading, checking and uploading the NIT are displayed.
Note: Only with the software extension MKS 1-00 can the type be set to Manual and a Network Information Table (NIT) be
read from the devices, edited and uploaded back to the devices. The MKS 1-00 must be installed by AXING support (for this
purpose, a connection with the Internet is necessary).