 Under Add unreferenced PIDs, click the green plus sign in the table header.
A line for entering the PID is inserted.
 Under Input, select one of the available input streams.
 Under In PID, enter an unreferenced PID.
 Select the output Modulator.
 Under Out PID, enter the output PID. The output PID can be the same or different from the input PID.
 Click on the green plus sign next to the line.
The entered data are inserted.
 If necessary, enter additional non-referenced PIDs.
The same input PID can be added to multiple outputs if needed. Output PID value can be set separately for each output. In the
example below, PID 7496 from the input stream 239.0.0.1:1234 is added to three outputs.
 Click SAVE after completing the entries.
This saves the entries in the headend.
Editing or deleting entries
 Click on the pencil icon to the right of the line.
You can now change Input, In PID, Modulator and Out PID