IX. Transport and storage
            The engine and the exhaust pipe are very hot during
operation and remain hot for a long time after the
pressure cleaner is turned off, therefore, do not touch
them. To prevent burns during handling and combus-
tion hazards during storage, allow the pressure cleaner
to cool down before handling and storing it.
TRANSPORTING
THE PRESSURE CLEANER
y Transport the pressure cleaner exclusively in a horizon-
tal position, suitably secured against movement and
impacts in the transportation area.
y Set the motor shut-off switch to the "OFF" position.
y The fuel supply valve must be closed and the fuel tank
lock must be firmly pulled tight.
y Never start up the pressure cleaner during transport.
Always take the pressure cleaner out of the vehicle prior
to starting it.
y When transporting it in an enclosed vehicle, always keep
in mind that under strong solar radiation and a higher
ambient temperature inside the vehicle, temperature
will increase extremely and there is a risk of combustion
or explosion of petrol fumes.
BEFORE STORING
THE PRESSURE CLEANER
FOR AN EXTENDED PERIOD OF TIME
y Protect it against direct sunlight.
y In the event that there is a risk of frost, disconnect the
water supply hose from the pressure washer, and start
the pressure washer, and immediately press
the trigger of the spray gun and for a period
of no more than 10 seconds express the
water from the pressure washer system. The
pressure washer must not run for longer
than 10 seconds so that it is not damaged by being run
without water.
y Drain all fuel from the fuel tank and fuel hoses, and
close the fuel valve.
y Purge carburettor.
y Change the oil.
y Clean the external part of the engine.
y Screw out the spark plug and allow approx. 1 teaspoon
of motor oil to flow into the cylinder, and then pull the
handle of the manual starter 2-3×. This will create an
even protective oil film in the area of the cylinder. Then
screw the spark plug back in.
y Pull on the handle of the manual starter and stop the
piston in the top end position. In this way, the exhaust
and suction valve will remain closed.
y Place the pressure washer into a safe dry room.
EN
X. Diagnostics
and troubleshooting
potential faults

ENGINE WILL NOT START

y Is the power switch in the "ON" position?
y Is the fuel valve for the supply of the given fuel open?
y Is there sufficient fuel in the tank?
y Is there a sufficient amount of oil in the engine?
y Is the ignition cable connector connected to the
engine's spark plug?
y Is the spark plug generating a spark?
y Do you have old stale petrol in the fuel tank? (Add a pet-
rol conditioner to the petrol and stir it in by moving the
pressure cleaner or by pouring another portion of the
fuel over it and allow it to act, see fig. 5. chapter IV.)
If the engine still will not start, purge carburettor (see above).
If you are unable to remedy the fault, have the repairs perfor-
med at an authorised service centre for the HERON® brand.
If you are unable to start the engine even after this, have
the repairs performed at an authorised service centre for
the HERON® brand.