Herunterladen Inhalt Inhalt Diese Seite drucken

Pump Medium; Temperatures And Ambient Humidity; Electrical Specification; Power Supply - EBARA Ego 2 slim Installations- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
3.2

PUMP MEDIUM

Pump medium can be pure water or a mixture of pure water and glycol, which is appropriate for central heating
system. Water must meet water quality standard VDI 2035. The medium must be free from aggressive or
explosive additives, free from mixtures of mineral oils and solid or fibrous particles. The pump should not be used
for pumping flammable, explosive media and in an explosive atmosphere. Permanent magnet rotor inside the
pump is prone to accumulating magnetic particles on its surface, which can lead to abrasion of bearings and rotor
can or even blocking the rotor. Although the pump is built in a way that the effect of magnetic particles is minimal,
failures of bearings, rotor cans and blocked rotors are not a subject of claims.
To improve pump resistance to magnetite we recommend the use of magnetite filter.
3.3

TEMPERATURES AND AMBIENT HUMIDITY

Ambient temperature
[°C]
Up to 25
Up to 30
Up to 35
Up to 40
Medium temperature should be higher or the same as ambient temperature, so that the
condensate does not gather on pump surface.
Operation outside allowed conditions may shorten pump lifetime and void the warranty.
3.4

ELECTRICAL SPECIFICATION

POWER SUPPLY

Pump
Ego 2 (TC) slim 32-120
Ego 2 (TC) slim 40-40
Ego 2 (TC) slim 40-80
Ego 2 (TC) slim 40-120
Ego 2 (TC) slim 40-180
Ego 2 (TC) slim 50-40
Ego 2 (TC) slim 50-80
Ego 2 (TC) slim 50-120
Ego 2 (TC) slim 50-180
Ego 2 (TC) slim 65-40
Ego 2 (TC) slim 65-80
Ego 2 (TC) slim 65-120
Ego 2 (TC) slim 80-40
Ego 2 (TC) slim 80-80
Ego 2 (TC) slim 100-40
Permitted ambient and media temperature:
Medium temperature [°C]
min.
max.
-10
110
-10
100
-10
90
-10
80
Electrical ratings
Rated
Rated
power
voltage
[W]
370
110
270
230 VAC ±
480
15 %, 47-
680
63Hz
160
Pumps can
370
operate at
560
reduced
830
voltage with
230
limited
560
power
810
(P=I
*U)
MAX II
390
800
550
22
Relative ambient humidity
<95 %
Rated
Rated current
current [A]
(IMAX II) [A]
1.8
6
0.9
6
1.3
6
2.3
6
3.4
6
1
6
1.7
6
2.5
6
3.6
6
1.1
6
2.6
6
3.5
6
1.8
6
3.5
6
2.4
6
Startup
Build-in
startup
circuit.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis