10.

Maintenance

10.1

Maintenance Information

The metering station is tested at the factory and when dispatched is in a technically
sound condition and in accordance with the specifications.
To maintain this condition, and for trouble free operation, the user must pay careful
attention to the content of these instructions.
Before any maintenance or repair tasks are carried out on the equipment, it is most
WARNING
important to ensure that it has been disconnected from the electricity supply and has
been de-pressurised. After parts have been replaced, a functional test is to be carried out.
Maintenance tasks on equipment that has been connected up should only be carried out
by qualified personnel.
CAUTION
When using hazardous substances the appropriate safety instructions are to be
observed. Operators must be equipped with their own personal safety equipment
(protective goggles, gloves, apron).
10.2

Maintenance Tasks

When carrying out maintenance tasks on the
the following points:
 Check for accumulation of dirt and foreign material
 Required applicator function is set
 Functioning of solenoid valves
 Check and, if necessary, clean nozzles and filters
 Functionality check of suction circuit (mesh filter and valve at lower input port,
protective cover)
 Suction and pressure valves on the pump
 Functionality check of the return hose from the pressure release valve.
The hose must have a free downward gradient.
 Check that the suction and pressure circuit connections are leak free.