Control System
7.1

Brief overview of configuration

The
DryExx Advanced
metering station in the 'General Parameters' menu item:
• The free allocation of 16 valves to the required system
• Number of packages per impulse of the optional meter
• System pre-tensioning time
 Ensures that all circuits are supplied with the same output pressure for the
conveyor belt lubricant
• System bleeding time
 Ensures that there is no leakage on the nozzle fittings
• Delay time for the 'empty' detector function
 No error message during a normal drum change
• Number of impulses of the optional oval gear meter
• Quantity of belt lubricant per impulse for the optional oval gear meter
Configuration of the following parameters: For each lubricating circuit in the 'Circuit
Parameters' menu item:
 Impulse time for spraying
 Pause time for spraying
Manual start of one impulse time by means of interrupting the pause time for each
lubricating circuit
All options are displayed in plain text on the various screens. Follow the instructions
NOTE
displayed.
7.2

Initial configuration

CAUTION
This warning applies to all points in chapter 7.2 Initial Configuration.
• You must carry out valve allocation as described in chapter
assignment for the start-up procedure. If you have not carried out valve allocation,
you cannot access the parameter sets.
• Each valve can only be allocated once.
• The following passwords are set when the system is delivered:
Ecolab
Customer
Operator
• During the initial configuration, these passwords must be changed in accordance
with customer specifications. For more information, see chapter Passwords. If the
passwords are not changed, procedure-relevant functions of the control system can
be accessed by unauthorised personnel.
Failure to observe any of the start-up points listed in section 2.4 Initial Configuration will
CAUTION
result in the invalidation of the guarantee.
417101634_Lubo-DryExx_Advanced
DryExx Advanced
®
enables the configuration of the following parameters: For the
7777
5555
3333
®
- 40 -
7.3.8.1.2.1
Valve
Rev. 07-01.15