12.9.2 Measure alternating currents (mA/µA
1. Switch the DMM on and select mA or µ mode.
2. Press SEL/
"AC" and "TRMS" appear on the display.
Æ
The table shows the different modes and potential measurement ranges. Select
Æ
the measurement range and corresponding measurement sockets.
Measurement mode
µA
mA
3. Insert the red test lead into the mAµA measurement socket. Insert the black test
lead into the COM measurement socket.
4. Connect the two measuring probes (de-energised) in series to the object that
you want to measure (e.g. generator, battery or circuit). The electrical circuit
must be disconnected before you connect the probes.
5. Reconnect the circuit. The measurement will appear on the display.
6. After measuring, disconnect the circuit and remove the test leads from the
measured object. Switch the DMM off.
to switch to AC mode.
Measurement range
0 - 6000 µA
6000 µA - 600 mA
)
Measurement sockets
COM + mAµA
COM + mAµA