Herunterladen Inhalt Inhalt Diese Seite drucken

Ex 23 Control Switch; Ghg238 - Eaton CROUSE-HINDS Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für CROUSE-HINDS Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Contakt arrangements
Ex 23 / Ex28 / Ex 29 switch
Switch mechanism
4
5
Special switch
mechanism
7
8
Explosion-protected distributions GHG 619; EXKO
1.25 Ex 23 control switch; GHG238 ....R....
Circuitry
Code
EU-Type Examination Certificate:
Marking acc� to 2014/34/EU
6011
and standard of series EN 60079:
6019
6060
IECEx type examination certificate:
Category of application
6062
standard of series IEC 60079:
6065
6033
Operating temperature:
6170
Tested ambient temperature range: (IIB)
Perm�ambient temperature in original packing:
. 021
Degree of protection to EN/IEC 60529:
Rated voltage:
. 023
Rated current:
Switching capacity acc. to AC 15 (EN 60947-5-1):
. 024
Switching capacity acc. to DC 13 (EN 60947-5-1):
Perm� short-circuit back-up fuse:
Design with gold-tipped contacts:
. 061
Supply terminals:
Test torques supply terminals:
. 063
Weight:
. 066
. 067
. 049
. 037
. 191
Switch actuator Ex 23
6
9
Drilling dimensions switch actuator Ex 23
BVS 13 ATEX E 107U
II 2 G Ex db eb IIB Gb
II 2 G Ex db eb IIC Gb
II 2 G Ex db ia/ib IIB Gb
II 2 G Ex db ia/ib IIC Gb
II 2 G Ex db eb I Mb
IECEx BVS 13�0108U
Ex db eb IIB Gb
Ex db eb IIC Gb
Ex db ia/ib IIB Gb
Ex db ia/ib IIC Gb
Ex db eb I Mb
(IIB)
-60 °C
���
(IIC)
-55 °C
���
-60 °C
���
(IIC)
-55 °C
���
-60 °C
���
IP 66
to max�500 V
10 A
230 V /
6�0 A
24 V /
6�0 A
16 A/gG to 500 V
to max� 400 mA
1x / 2x 0�5 - 2�5 mm²;
2�0 Nm
1 level
approx� 0�20 kg approx� 0�35 kg
84
25,5
GB
+80 °C
+80 °C
+55 °C
+55 °C
+80 °C
(installed condition)
400 V
/
6,0 A
230 V
/
0,4 A
2 levels
58,5
Ø 102
31
Switch actuator GHG264
Ø 132
56,5
Ø 102
Switch actuator GHG266
57

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Crouse-hinds ghg 619Crouse-hinds exko

Inhaltsverzeichnis