Contact arrangement - ELCB (RCCB)
(other variants possible� observe type lable)
1/2
3/4
2/1 4/3
2-pole
1/2
3/4
5/6
7/8/N
2/1 4/3 6/5
8/7/N
4-pole N-right
N
1/2
3/4
5/6
N
2/1 4/3 6/5
4-pole N-left
Contact arrangement
ELCB with circuit breaker
(other variants possible� observe type lable)
1/2
N
2/1 N
1-pole + N
1/2
3/4
2/1 4/3
2-pole
The technical data relates to standard built-in apparatus�
- If other built-in apparatus is used, the technical data sheets
or the data on the type label shall be observed�
Explosion-protected distributions GHG 619; EXKO
1.5.1 ELCB (RCCB), 2 and 4-pole; GHG624
Type:
Alternating current and pulse current
acc IEC 755
All current sensitive
acc IEC 755
Rated voltage:
Main contact
Rated current:
Main contact
Rated short-circuit protection: I cn:
Back-up fuse:
I
= 25 A
n
I
= 40 A
n
Tripping current:
Component size:
Weight approx:
The technical data relates to standard built-in apparatus�
If other built-in apparatus is used, the technical data sheets or the data on the type label shall be observed�
Tripping characteristics see last page� Additional facilities require a larger housing components�

1.5.2 RCBO with Circuit breaker, 2-pole; GHG625

Type:
Rated voltage:
Main contact
Rated current:
ELCB
Circuit breaker
Rated short-circuit protection: I
Fuse:
ELCB
I
= 25 A
n
I
= 40 A
n
Circuit breaker
*The technical data relates to standard built-in apparatus�
If other built-in apparatus is used, the technical data sheets or the data on the type label shall be observed�
Tripping current ELCB:
Component size:
Weight approx:
Tripping characteristics see last page� Additional facilities require a larger housing components�
1.5.3 Maximum contact voltage UL für FI, FI/LS
Maximum contact voltage
25 V
50 V
Tripping characteristics see last page� Additional facilities require a larger housing components�
GHG 624���R0���
serie A
RCCB
Type A
RCCB
Type B
230/400 V AC ���
240/415 V AC
to 63 A
10 kA
max� 100 A gG
--
--
30 mA, 100 mA, 300 mA, 500 mA
2
3
0�96 kg
1�24 kg
GHG 625���R����
serie A
up to 400 V
up to 63 A
up 0�5 A
to 32 A (40 A)
:
up to 10 kA depend on circuit breaker*
cn
max� 100 A gG*
--
--
dep� on rated current up to 100 A gG*
30 mA, 100 mA, 300 mA, 500 mA
2
3
0�96 kg
1�24 kg
maximum permissible earth resistance at
rated residual current in Ohm
10 mA
30 mA
2500
833
5000
1666
GB
GHG 624���R1���
serie E
to 240/415 V
to 40 A
25 A gG/gL*
40 A gG/gL*
4
1�62 kg
GHG 625 2103 R ����,
GHG 625 3107 R ����,
GHG 625 3108 R ����
serie E
up to 240/415 V
up to 32 A
up 0�5 A to 40 A
25 A gG/gL*
40 A gG/gL*
4
1�62 kg
100 mA
300 mA 500 mA
250
83
50
500
166
100
45