17. Troubleshooting

Fault

Possible cause

Saw blade is loose after
Fixing nut not tight enough
the motor is switched off
Motor does not start
Mains fuse blown
Extension cable defective
Connection to the motor or switch not OK
Motor or switch faulty
Motor not supplying
Cross section of the extension cable insufficient
power, fuse tripping
Overload due to blunt saw blade
Burnt areas on the
Blunt saw blade
cutting surface
Incorrect saw blade
14
GB/IE
Remedy
Tighten fixing nut, right-hand thread
Check mains fuse
Replace the extension cable
Have this checked by an electrician
Have this checked by an electrician
See "Electrical connection"
Replacing the saw blade
Have an authorised sharpening service sharpen the
saw blade or replace it
Replace saw blade