Functional Principle, Technical Data
3.3

Technical Data

Model
Measuring range
Min. target size
2
Distance light source - receiver
(free space)
1
Measuring distance (target - receiver)
Measuring rate
Resolution
Linearity
2
Repeatability
4 5
Light source
Laser class
Permissible ambient light
Analog output
Digital interface
Switching output
Signal input
Connector
Light source
Mounting
Temperature range
Supply voltage
Maximum power consumption
optoCONTROL 1200/1201
ODC 1200 (axial model)
mm
2
5
mm ≥ 0.03
≥ 0.05
µm
8
10
±2 % FSO
≤ 16 µm ≤ 20 µm ≤ 40 µm ≤ 60 µm
Switching output PNP dark switching and NPN light switching (max. switching frequency 60 kHz)
Receiver
Mounting rail, adjustment plates (see accessories), mounting holes
Storage
Operation
ODC 1200/90 (90 ° model)
10
16
2
3
≥ 0.1
≥ 0.15
≥ 0.03
min. 30 mm ... 150 mm
20 mm ... 2000 mm; optimum distances: 20, 50 mm
100 kHz (-3 db)
20
30
8
±3.5 % FSO
±2 % FSO
≤ 2 µm
Semiconductor laser 670 nm (red)
Laser class 1 (P
≤ 0.39 mW) according to IEC 60825-1:2014
max
≤ 5000 lx
0 ... 10 VDC (adjustable amplification, depending on direction)
Ethernet
, EtherCAT
7
adjustable button
Laser control (light source) 0 - 5 VDC
4-pin M12 socket for power supply, analog and digital output
4-pin socket M12 for supply and laser control
-20 ... +70 °C (-4 ... +158 °F)
0 ... +50 °C (+32 ... +122 °F)
12 ... 32 VDC
< 0.3 A
5
10
16
≥ 0.05
≥ 0.1
≥ 0.15
max. 2.5 m
1
1
10
20
30
±3.5 % FSO
≤ 20 µm ≤ 40 µm ≤ 60 µm ≤ 100 µm ≤ 140 µm
6
(max. 14 bits/4k Sps)
7
ODC 1201
20
30
≥ 0.15
≥ 0.2
50
70