Initial Commissioning Of The Conel Flow Rain-Champion; Security - Conel Flow Regen-Meister Bedienungsanleitung

Mit füllstandsensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

74
• Faulty electrical connections;
- check the connection of the power supply - is voltage (230V/50Hz);
- as soon as the required mains voltage is attached, the „POWER" LED lights up.
• The pump housing is not fi lled with water.
- the safety system has been triggered and the LED „POWER" lights up, the LED"ERROR" lights
up.
- Fill pump housing with water and then restart (RESET button press).
• The pump is blocked.
- the LED „POWER" as well as the LED „ERROR" light up, the safety system has been triggered. By
pressing the „RESET - Button" lights the „ON" LED, but the pump does not start. In this case,
contact technical support.
• Air inlet at the pump;
- pressure is signifi cantly lower than the nominal pressure or there are constant fl uctuations. The
safety system stops the operation of the pump and triggers an error message;
- The LED „POWER" and the LED „ERROR" light up.
- Check the sealing of the connectors and the seals of the intake shaft.
• Pump is constantly running:
- possible leakage in the piping system;
- check all sampling points for leaks – especially hoses and mobile sampling points (e.B. garden
syringe, etc.).
9
INITIAL COMMISSIONING OF THE
CONEL FLOW RAIN-CHAMPION
9.1

SECURITY

Risk:
• All commissioning activities may only be carried out by professional and
• Do NOT wear your personal protective gear and do NOT work with wet hands
• Before starting work of any kind, please ensure that the power supply has been
• As soon as the Conel Flow Rain-Champion is put into operation, no persons
• Ensure that the Conel Flow Rain-Champion cannot be put into operation wit-
• Make sure that the electrical connectors are in the fl ood-proof area or are
• Refer to unauthorized persons (especially children, adolescents) or animals from
Attention:
• The temperature of the conveying fl uid shall not exceed the maximum tempera-
• The Conel Flow Rain-Champion must not be operated in impure water under
knowledgeable personnel who have been suffi ciently informed by studying the
operating instructions in-depth;
or wet feet or stand in the water – avoid a fatal electric shock.
interrupted (e.g. pull the power plug) and secure it again against unauthorized or
unintentional re-engagement;
or animals may be in the conveying medium (storage) – danger to life due to
electric shock;
hout authorisation or unintentionally during commissioning;
protected from moisture.
the fi eld of work and activity.
ture specifi ed in the technical data;
any circumstances.