Herunterladen Inhalt Inhalt Diese Seite drucken

KEB F5 Betriebsanleitung Seite 34

Combivert
Vorschau ausblenden Andere Handbücher für F5:
Inhaltsverzeichnis

Werbung

Anhang
Branch Circuit Protection:
Listed (NKJH) Type E Self Protected Manual Motor Controllers. Type and manufacturer and
electrical ratings as specified below:
240V devices:
Inverter
model
F5/F6
13
14
480V devices:
Inverter
model
F5/F6
12
13
14
15
16
(#) all Drives series which use a Self Protected Motor Controller rated 480Y/277V are sui-
table for 480y/277V sources only.
Only for F6 housing E series:
"For Connector CN300 on Control Board:
Only use KEB Cable assembly Cat.No. 00H6L41-0xxx or 00H6L53-2xxx (where x = any digit)
and use strain relief provisions as described below:"
Strain relief at housing E by use of mounting kit E0F5T88-0001 or -0002
D - 34
Type E Self Protected Manual Motor Controllers for Drive
series inverters F5-E and F6-E.
Drive input
Self Protected
rating
Manual Motor Controller Type
and manufacturer
240V/ 3ph
PKZMO–32E, Eaton Industries
240V/ 3ph
PKZM4–50E, Eaton Industries
Drive input
Self Protected
rating (#)
Manual Motor Controller Type
and manufacturer
480V/ 3ph
PKZMO–25E, Eaton Industries
480V/ 3ph
PKZMO–25E, Eaton Industries
480V/ 3ph
PKZMO–25E, Eaton Industries
480V/ 3ph
PKZM4–40E, Eaton Industries
480V/ 3ph
PKZM4–40E, Eaton Industries
Self Protected
Manual Motor Controller
rating
230V/3ph, 10 hp
230V/3ph, 15 hp
Self Protected
Manual Motor Controller
rating
480Y/277V, 15 hp
480Y/277V, 15 hp
480Y/277V, 15 hp
480Y/277V, 30 hp
480Y/277V, 30 hp