MALFUNCTIONS
Always disconnect the mains voltage from the
machine during maintenance and cleaning. Never
use water or inflammable liquids to clean the machine. Brush
the machine clean with a brush.
PERIODIC MAINTENANCE OF THE SAW BENCH
PREVENTS UNNECESSARY PROBLEMS!
In the event of the machine not working properly, we
give below a number of possible causes and the remedies
for them:
1. The electric motor is overheating.
The motor is being overloaded because the
workpiece diameter is too large.
Allow the motor to cool down.
The cooling air slits in the motor are clogged with dirt.
Clean the cooling air slits.
The workpiece is being pushed too quickly against
the saw blade.
Push the workpiece slowly against the saw blade.
The motor is defective.
Take the machine to your Ferm dealer for inspection
and/or repair.
2. Machine does not work when switched on.
The motor has been switched off by the thermal
protection system.
Let the machine cool down and switch it on again.
Interruption in the mains connection.
Check mains connection for fracture.
Damaged switch.
Take the machine to your Ferm dealer for inspection
and/or repair.
3. It is difficult to move the work in a straight line
past the saw blade and the kerf is irregular.
The saw blade is bent or blunt.
Replace the saw blade.
The rip fence is not fastened properly.
Clean the rip fence and fasten it securely.
4. The workpiece begins to vibrate excessively
during sawing.
The saw blade is getting overheated or deformed.
Replace the saw blade.

MAINTENANCE

During maintenance and cleaning always remove
the mains plug from the socket. Never use liquids
when cleaning electrical parts of the saw bench.
Cleaning
Keep the ventilation slots of the machine clean to
prevent overheating of the engine. Regularly clean the
machine housing with a soft cloth, preferably after each
use. Keep the ventilation slots free from dust and dirt. If
the dirt does not come off use a soft cloth moistened
with soapy water. Never use solvents such as petrol,
alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
6
Lubrication
The machine requires no additional lubrication.
Faults
Should a fault occur, e.g. after wear of a part, please
contact your local Ferm dealer.
In the back of this manual you find an exploded view
showing the parts that can be ordered.
ENVIRONMENT
In order to prevent the machine from damage during
transport, it is delivered in a sturdy packaging. Most of
the packaging materials can be recycled. Take these
materials to the appropriate recycling locations.
Take your unwanted machines to your local Ferm-
dealer. Here they will be disposed of in an
environmentally safe way.
GUARANTEE
The guarantee conditions can be found on the separately
enclosed guarantee card.
ı
( UK )
CE
DECLARATION OF CONFORMITY
We declare under our sole responsibility that this
product is in conformity with the following
standards or standardized documents
EN55014-1, EN55014-2,
EN61000-3-2, EN61000-3-3
EN61029-1, 61029-2-1
in accordance with the regulations.
98/37EEC,
73/23/EEC,
89/336EEC
from 13-10-2003
GENEMUIDEN NL
W. Kamphof
Quality department
4.
.
.
Ferm
.
,
.
,
.
,
,
.
o
Ferm.
,
.
Ferm
Ferm
.
ı
CE
,
.
EN55014-1, EN55014-2,
EN61000-3-2, EN61000-3-3
.
EN61029-1, 61029-2-1
.
,
,
.
13-10-2003
GENEMUIDEN NL
W. Kamphof
Quality department
.
,
,
.
.
.
.
( GR )
:
:
98/37/EEC
73/23/EEC
89/336/EEC
75

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fzb-205/1000

Inhaltsverzeichnis