3 - TROUBLESHOOTING

In case of water leaks or anomalous functioning immediately cut off the power supply and close
the water taps.
Should one of the following anomalies occur, contact an authorised service centre or an authorised
qualified person, but do not intervene personally.
- The front heating plate does not reach a uniform temperature during heating.
- The ventilation does not activate even if there is hot or cold water in the hydraulic circuit.
- The appliance leaks water during the heating function.
- The appliance leaks water only during the cooling function.
- The appliance makes an excessive noise.
- There are formations of dew on the front panel.

3.1 - TABLE OF ANOMALIES AND REMEDIES

Do not try to repair the equipment by yourself.
If the problem has not been solved, please contact your local retailer or the closest assistance
service.
MALFUNCTION
The front heating plate does not
reach a uniform temperature
during heating.
A delayed activation of the
ventilation respect to the new
temperature or function settings.
The ventilation speed increases
or decreases automatically.
The appliance does not activate
the ventilation.
The ventilation does not activate
even if there is hot or cold water
in the hydraulic circuit.
EN - 48
CAUSE
- Air present in the inner circuit
of the appliance.
- The circuit valve needs some
time to open and as a result the
hot or cold water takes time to
circulate in the appliance.
- The electronic control adjusts
the comfort level regularly.
- No hot or cold water in the
system.
- The hydraulic valve remains
closed.
- the fan motor is blocked or
burnt out.
SOLUTION
- Release the air several times
(see sect. 2.11).
- Wait for 2 or 3 minutes to open
the circuit valve.
- Wait for the temperature
adjustment or in case of
necessity select the silent
function.
- Check that the water boiler
or cooler are functioning
correctly.
- Dismount the valve body and
check if the water circulation
is restored.
- C h e c k
t h e
w o r k i n g
e f f i c i e n c y o f t h e v a l v e
by powering it separately
with 220V. If it activates
the problem could be the
electronic control.
- Check the windings of the
motor and the free rotation of
the fan.
>>>>