Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS C-60 3 Serie Handbuch Seite 96

Elektronische identifikations-systeme
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C60_3-025_825645_1310_e.p65
91
Mounting the
BIS C-6023
processor
92
Wiring for the
BIS C-6023
processor
The ground connector should be connected to earth directly or
through a RC combination depending on the system (potential
counterpoise).
When connecting the bus leads, make sure that the shield has pro-
per connection to connector housing.
92
english
BIS C-6023
Mounting Processor
The processor is mounted using 4 M4 screws.
X1
X2
X3
60
ca. 20
BIS C-6023
Schnittstelleninformationen / Anschlusspläne
Connection for read/write head 2
Connection for read/
Head 2 Head 1
write head 1
ON OFF
OFF ON
S2
1
2
1
2
3
X1
4
5
6
7
8
S1
Head 1
X2
Head 2
RS 232
Head
X4
X3
X4
Head 2 Head 1
M4
X4
63
100
X1, supply voltage,
digital input
X2, DeviceNet output
X3, DeviceNet input
Function
ground FE
X4, Service interface
4
3
2
1
91
english
Pin
Function
1
+Vs
2
–IN
3
–Vs
4
+IN
5
n.c.
n.c. = do not
connect!
Pin
Function
1
Drain
2
+VS1
3
–VS1
4
CAN_H
5
CAN_L
Pin
Function
1
Drain
2
+VS1
3
–VS1
4
CAN_H
5
CAN_L
Pin
Function
1
2
TxD
3
GND
4
RxD

Werbung