Operation of the device
Pipe Lining
- > Lining material
Continue..
Main Menu..
Pipe Lining Thick
- > Pipe Lining thickness
Continue..
Main Menu..
Fluid Type
- > Select fluid type
Continue..
Main Menu..
Fluid Temperature
- > Fluid Temperature
Continue..
Main Menu..
Heat Meter
- > Installation Side
Sensor Type
Continue..
Main Menu..
Summary
- > Site: Quickstart
Sensor seperation: 69.9mm
Pipe OD: 114.3mm, ID 98.3mm
Sensor type A-ST, Mode: Reflex
Fluid type: Water @14.0 C
Press < - to continue, <> to select sens.
ATTACH SENSORS
Attach Sensor Set
Red Connector UpStream
Press
Key to go to Flow Reading
NOTICE
The SENSOR SELECTION menu can be entered by use of the Up/Down scroll keys. This allows the type and mode of the sensors
being used to be selected. This menu will be entered automatically if the entered pipe OD and/or temperature are not valid for the
currently selected sensors.
28
DD-MM-YY
HH:MM:SS
Glass
DD-MM-YY
HH:MM:SS
1.0
mm
DD-MM-YY
HH:MM:SS
Water
DD-MM-YY
HH:MM:SS
14.0 C
DD-MM-YY
HH:MM:SS
Hot Sensor
PT100
DD-MM-YY
HH:MM:SS
DD-MM-YY
HH:MM:SS
Select CONTINUE and press the ENTER key.
8.
Enter the fluid temperature (-30 – 135.0 °C) at the point the
meter is installed.
Select CONTINUE and press the ENTER key.
9.
HM versions only: Specify how the Heat meter is
configured: Hot Sensor/ Cold Sensor/ Fluid Temperature.
Program the unit with the temperature of the fluid at the
point where the flow meter is installed to account for any
variations in relative density and specific heat capacity. If
the meter is installed at a point some way from either the
hot of cold sensor, select the temperature entered in the
previous step.
Select CONTINUE and press the ENTER key.
10.
The Summary screen is displayed. This displays a
summary of the entered parameters and informs you of
the type of sensor to be used, the mode of operation and
the distance to set up between the sensors.
In this example, A-ST (A standard) sensors are
recommended, operating in the 'Reflex' mode, spaced at
69.9mm apart.
Note: Do not press the enter key until the correct
transducers are fitted and connected to the instrument. If
the data contains a mistake, press the delete key to return
to the main menu and restore the previous settings.
11.
If you prefer to use a different configuration, press the UP
or DOWN arrow key to select a different sensor set and
mode
Operating Instructions