Herunterladen Inhalt Inhalt Diese Seite drucken

Operation Of The Device; Using The Quick Start Menu - GF PF220 V2 Betriebsanleitung

Ultraschall-durchflussmessgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 69
Operating Instructions
8

Operation of the device

8.1

Using the quick start menu

The quickest way to set up the flowmeter and access the FLOW READING screen.
If the point at which you intend to take the measurement is likely to require regular monitoring it is best to set it up as a 'Site' with-
in the flowmeter, which then stores the site parameters.
Before you can use the flowmeter you need to obtain the following details (this information will be required when setting up the
Quick Start menu):
Pipe outside diameter.
Pipe wall thickness and material.
Pipe lining thickness and material.
Type of fluid.
Fluid temperature.
8.1.1
Entering the site data
PF330 MAIN
- > Quick start..
View / Edit Site Data..
Setup Instrument..
Data Logger..
Read Flow..
Read Energy..
Pipe Outside Di
- > Pipe outside diameter
Pipe circumference
Continue..
Main Menu..
Pipe Wall Thick
- > Pipe wall thickness
Continue..
Main Menu..
Pipe Wall Mater
- > Pipe wall material
Continue..
Main Menu..
DD-MM-YY
HH:MM:SS
DD-MM-YY
HH:MM:SS
114.30
mm
359.08
mm
DD-MM-YY
HH:MM:SS
8.00
mm
DD-MM-YY
HH:MM:SS
PVC-U
1.
Select Quick start from the MAIN MENU and press the
ENTER key. You will then be presented with a series of
screens in which to enter the data mentioned above.
2.
Enter the pipe's outside diameter (15 – 2000 mm or its
circumference (47.1 – 6283.2 mm). When you enter one
value the other is calculated from it.
Select CONTINUE and press the ENTER key.
3.
Enter the pipe wall thickness (0.5 – 50 mm).Select
CONTINUE and press the ENTER key.
4.
Choose the pipe wall material: Plastic/ Cast Iron/ Ductile
Iron/ Copper/ Brass/ Concrete/ Glass/ Other (m/s)/ Mild
Steel/ S'less Steel 316/ S'less Steel 303
If the material is not listed, select Other (m/s) and enter
the propagation rate of the pipe wall material in meters/
sec. Contact GF if this is not known.
Select CONTINUE and press the ENTER key.
5.
Identify the pipe lining material from the following options:
None/ Rubber/ Glass/ Epoxy/ Concrete/ Other (m/s).
If the material is not listed, select Other (m/s) and enter
the propagation rate of the pipe wall material in meters/
sec.
Select CONTINUE and press the ENTER key.
6.
If no lining material was entered, go to step 7. Otherwise,
enter the lining thickness (0 – 40 mm).
Select CONTINUE and press the ENTER key.
7.
Select the fluid type from the following options: Water/
Glycol/ water 50%/ Glycol/ water 30%/ Lubricating oil/
Diesel/ Freon/ Other (m/s).
If the fluid is not listed, select Other (m/s) and enter the
propagation rate of the fluid in metres/sec.
Note: If Other is selected, enter the speed of sound (SoS)
in metres per second, of the wall material. After entry of
the SoS, the user will be taken to the following screen as
would have been the case if another selection was made.
Operation of the device
27

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pf330 v2

Inhaltsverzeichnis