2.4 Installing the pump / lubricating sealing
areas:
The electrical components of the system are
packaged separately in order to prevent any da-
mage during shipping. The pump should be pla-
ced in the tank and secured with the 3 turn
fasteners. The swivel connection should be inser-
ted into the gasketed opening and secured with
the one-handed closure (see Illustration 9). Be
sure that about 1 meter of pump cable slack is
left inside the pumping tank so that if the pump
needs to be removed it can be pulled out of the
tank and placed on the floor nearby.
Caution
Make sure that the pump is set properly into the
pump hole and secured with the three turn fas-
teners.
1
2
2. Installation
Run the see-through air pressure hose from the
Aqualift F through the conduit pipe. Make sure
that the air pressure hose is not bent or kinked
and has a continuous positive slope from the
pump to the control unit (no coils or loops). The
optical sensor should also be inserted in its
appropriate opening which will first require that
the protective plug is removed. After connecting
the power cable, optical sensor cable and the
see-through air pressure hose to the control unit
and connecting power to the control unit, the
system is operational.
Caution
Before connecting the cables to the control unit
be sure to observe the instructions in the instal-
lation and operation manual of the control unit.
ill. 9
ill. 10