Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnostics Led - tau K122M Installationsanleitung

Schalt und steuertafel fuer den getribemotor speed 2
Vorschau ausblenden Andere Handbücher für K122M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
DL1
PEDESTRIAN button red LED signal
DL2
OPEN/CLOSE button red LED signal
DL3
ERRORS red LED signal
DL4
STOP button green LED signal
DL5
PHOTOCELL green LED signal
DL6
SENSITIVE EDGE green LED signal
1- The automation does not start
a- Check there is 230Vac power supply with the multimeter;
b- Check that the NC contacts of the card are actually normally closed (3 green LEDs on);
c- Set dip 6 (phototest) to OFF;
d- Increase the FR trimmer to the limit;
e- Check that the fuses are intact with the multimeter.
2- The radio control has very little range
a- Connect the radio aerial to the terminals of the receiver card and not to terminals 16-17
of the control card (for frequency 433,92 MHz);
b- Check that the ground and the aerial signal connections have not been inverted;
c- Do not make joints to increase the length of the aerial wire;
d- Do not install the aerial in a low position or behind walls or pillars;
e- Check the state of the radio control batteries.
3- The gate opens the wrong way
Invert the motor connections on the terminal block (terminals 23 and 24);
MALFUNCTIONS: POSSIBLE CAUSES AND SOLUTION
K122M

DIAGNOSTICS LED

19