BOS R254K-UUI-RS10-S4
Photoelectric Sensors
6
System Functions (continued)
6.8

Profile Characteristic

6.8.1
Description
Profile Characteristic is a readable parameter that provides
information about which IO-Link profiles are supported. It
is used mainly to allow profile function modules of the
control unit to detect which profile or functions on the
device are available.
This parameter is defined in the IO-Link specification.
6.8.2
ISDU
Name
Index
Profile Characteristic
0x000D (13)
Tab. 6-28: Profile Characteristic – ISDU
The parameter can be read via subindex 0 and consists of
multiple profile indices and function classes (each 16-bit
values).
If a profile ID is specified, this means that all included
function classes are supported. If only sub-functions are
supported, these are output explicitly as an individual
function class.
The following function classes are supported:
Variant
Function Class ID
3...5
0x0001
0x4000
0x800C
Tab. 6-29: Profile Characteristic – supported function classes
All individual functions are described in this guide.
For more exact descriptions of the profiles, refer to the
corresponding profile specifications (see www.io-link.com).
www.balluff.com
Subindex
Access
0
R
Name
Generic Profiled Sensor
Identification and Diagnosis
Transducer Disable
Length
Data Type
Storage
8 bytes
UINT16[]
Data
Default
n/a
english
81