Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS R254K-UUI-RS10-S4 Bedienungsanleitung Seite 148

Io-link-konfiguration
Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-RS10-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-RS10-S4
Photoelectric Sensors
5
Secondary Device Functions (continued)
The objective of this function is the detection of larger
vibration deviations that arise between normal and
abnormal operation as well as the detection of trends
(change of the values over time).
The accuracy of the measurement is limited by the
application, because the device is mounted to perform the
primary function (e.g., optical distance measurement) and
not as a sensor for vibration measurement. Thus, not only
the vibrations of the vibration source that is to be
measured, but also the vibrations of the entire mechanical
system are measured.
Fig. 5-11: Trend analysis
5.12.3 Process Data
Object ID
Name
0x004A (74)
Vibration Level
0x004B (75)
Vibration Alarm Status
Tab. 5-60: Vibration detection – Process data
The unit for Vibration Level is [mm/s]
The vibration alarm status flag is without units.
62
english
This function is based on the ISO-10816-3 standard, but
for a detailed vibration analysis Balluff offers special
sensors.
The product family is designed such that it offers complete
monitoring functionality, whereby the status monitoring is
the primary function of the sensor and it is mounted on the
object or on the machine.
Description
Vibration level
Vibration alarm status
Direction
Input
Input

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis