Photoelectric Sensors
5
Secondary Device Functions (continued)
5.10

Internal Temperature

5.10.1 Description
The device has internal temperature monitoring. This
records the device temperature as well as the maximum
and minimum values since production and since the last
time the device was restarted.
An upper and a lower threshold value can be defined for
the device temperature module. If the threshold is
exceeded or if device limit values are exceeded or
undercut, the device triggers IO-Link events.
The internal device temperature is measured in the
device and is therefore higher than the ambient
temperature. The level of this increased
temperature depends on the ambient temperature,
the ventilation of the device and the device
settings.
5.10.2 Process Data
Object ID
Name
0x0050 (80)
Device Temperature
Tab. 5-49: Internal temperature – Process data
5.10.3 ISDU
Name
Device Temperature
0x0052 (82)
Device Temperature
Minimum Device
Temperature Since
Reset
Maximum Device
Temperature Since
Reset
Lifetime Minimum
Device Temperature
Lifetime Maximum
Device Temperature
Device Temperature
0x0053 (83)
Alarm Configuration
Lower Alarm Level
Device Temperature
Upper Alarm Level
Device Temperature
Tab. 5-50: Internal temperature – ISDU (overview)
56
english
Description
Current device temperature in °C.
Index
Subindex
Access
0
R
1
R
2
R
3
R
4
R
5
R
0
R/W
1
R/W
2
R/W
Length
Data Type
Data Storage
10 bytes
2 bytes
INT16
2 bytes
INT16
2 bytes
INT16
2 bytes
INT16
2 bytes
INT16
4 bytes
2 bytes
INT16
2 bytes
INT16
Direction
Output
Default
n/a
n/a
n/a
n/a
n/a
n/a
Yes
No
0x0055 (85)
No
0xFFF6 (−10)