BOS R254K-UUI-RS10-S4
Photoelectric Sensors
5
Secondary Device Functions (continued)
5.12.4 ISDU
Name
Vibration Level
0x210E (8462)
Vibration Alarm
0x210F (8463)
Configuration
Vibration Alarm Enable
Vibration Alarm
Threshold
Vibration Alarm Status
0x2110 (8464)
Tab. 5-61: Vibration detection – ISDU
Vibration Level
Vibration level, primarily the calculated v-RMS value (root
mean square)
Unit: [mm/s]
Minimum value: 0.0
Maximum value: 1770.0
Vibration Alarm Enable
If the parameter is set (TRUE), the vibration level is
compared with the vibration alarm threshold value. If the
vibration exceeds the threshold value, an event is created
and sent.
0 = alarm deactivated
1...255 = alarm activated
Default = 0
Vibration Alarm Threshold
Threshold value of the vibration for triggering an event. The
comparison is performed for each axis and variable with
logical OR-link.
The hysteresis is fixed and is based on time (not on
amplitude). If the vibration value exceeds the threshold
value for 50 ms, the alarm is activated. Objective:
debouncing and avoidance of shock values.
Unit: [mm/s]
Minimum value: 0.0
Maximum value: 1770.0
Vibration Alarm Status
The status flag is TRUE if the vibration exceeds the alarm
threshold value.
0 = no alarm
255 = alarm
www.balluff.com
Index
Subindex
Access
0
0
1
2
0
Length
Data Type Data Storage
R
4 bytes
FLOAT32
R/W
5 bytes
R/W
1 byte
BOOL
R/W
4 bytes
FLOAT32
R
1 byte
BOOL
5.12.5 Events
Event
Event
Code
Type
0x8CD1
Warning
(36049)
Tab. 5-62: Vibration detection – Events
This event indicates that the measured vibration value
(v-RMS) exceeds the specified threshold value. The
machine should be inspected, since the vibration value is
above the normal value. The status of the device itself is
OK, it is functioning properly.
The higher vibration is caused outside of the device. The
primary goal is the detection of trends, changes to the
vibration alarm value (see Fig. 5-11 on page 62 yellow
line).
Default
n/a
Yes
No
0
No
0.0
n/a
Description
Device Status
Vibration alarm
0 – Device is
operating
► Check
properly.
machine.