15. Troubleshooting

15.1. Error messages

The sauna control unit is equipped with diagnostic software which monitors system
statuses when it switches on and during operation. As soon as the diagnostic
software identifies an error, the sauna control unit switches the sauna heater off.
Errors are indicated by a recurring warning tone and by flashing of the symbols 2
to 8. Furthermore, the error number appears in the additional display 1.
Switch the sauna control unit off using the On/Off switch 6 and rectify the error
before switching the sauna control unit on again.
The following table describes the possible errors and their causes. If necessary,
quote the error number to your customer service specialist.
Error
001
Safety cut-out
002
Overheat cut-out
4F1
Heater sensor error
005
Foil sensor error
6F2
Bench sensor error
007
Humidity sensor error
008
Foil sensor
excess temperature
bEr
Communication error
Description
Cause/Remedy
An object has been placed on the sau-
na heater. Remove any objects before
starting up the sauna heater again.
If no safety cut-out is fitted, note 5.11
on page 31.
The maximum temperature of 139 °C
has been exceeded above the heater.
Defective heater sensor, poor contact,
or short circuit.
Defective foil sensor, poor contact,
or short circuit.
Defective bench sensor, poor contact,
or short circuit.
Defective humidity sensor, poor contact,
or short circuit
The maximum foil temperature
of 100 °C was exceeded.
Check the cables between the power
unit and the control panels.