Instructions for use for the user

10.18. Activating standby for remote operation

EN 60335-2-53 specifies that sauna control units with a remote start function
must be set manually to "Standby for remote operation" mode. This activation
must take place again after each remote start and stop procedure. Perform the
following steps:
1. Make sure that the sauna control unit is in standby mode.
2. Press the On/Off button A and the mode button D simultaneously for about
3 seconds.
► In the display 1 "rc" (remote control) flashes and the remote control
symbol 9 flashes on the optional control panel for the additional output
(only Pro D2i/Pro D3i).
► The sauna control unit is then ready to be started and stopped using
a remote start signal.
► After a remote start and stop, the "rc" display and the remote start symbol
goes out and the mode has to be activated again.
To cancel the "Standby for remote control" function, press the On/Off
button A for about 3 seconds.

10.19. Changing the settings

You can change the settings at any time during operation.
1. Select the function you wish to change by pressing the mode button D.
2. Enter the desired setting using the plus button B and the minus button C.