Installation instructions, for professionals only

8.2. Settings on the technician menu

Opening the technician menu
Additional settings can be made on the technician menu. To access the techni-
cian menu, perform the following steps:
1. Switch on the power supply unit. Press the On/Off button F.
► The sauna control unit is in stand-by mode.
► The display 1 on the control panel shows "---".
2. Press the plus B, minus C and On/Off A buttons simultaneously.
► The display 1 on the control panel shows "SEt"
► The Temperature symbol 5 and the user program symbol 4 light up.
The settings are saved as soon as you close the technician menu (see
"Exiting the technician menu" on page 43) and the power unit has
been switched off for about 10 seconds (see "Switching off the power
supply unit" on page 60).
Decreasing the maximum temperature
The preset temperature can be set to between 30 °C and 110 °C as standard. If
you wish to decrease the maximum temperature from 110 °C to 105 °C, 90 °C
or 80 °C, perform the following steps:
1. Open the technician menu (see page 38).
2. Select "tHI" by pressing mode button D.
3. Press the On/Off button A.
4. Select the desired value with the plus button B and the minus button C.
● "110" °C maximum temperature (standard)
● "105" °C maximum temperature
● „90" °C maximum temperature
● „80" °C maximum temperature
5. Confirm the selection by pressing the On/Off button A.
6. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
7. Then switch the power unit off for about 10 seconds.
p. 38/70