ID71
Unrecover-
Incorrect MPPT
PvConfigSet-
mode set.
Wrong
ID72-
(Reserved)
ID73
ID74
Urecover-
The DC current is
IPVInstant
too high, an error
cannot be reset.
ID75
Unrecover-
The EEPROM is
WRITEEE-
not recoverable.
PROM
ID76
Unrecover-
The EEPROM is
READEE-
not recoverable.
PROM
ID77
Unrecover-
The relay has a
RelayFail
permanent fault.
ID78-
(Reserved)
D80
REFUsol 50K-3T
982081 | 03 | 2021-03
Check if the MPPT mode (Parallel or Independent) is set correctly according to the PV
system configuration, change if necessary.
ID74-ID77 are internal faults of the inverter, switch off the DC switch, wait 5 minutes
and switch on the DC switch again. If no troubleshooting is possible, contact REFU
Service.