Tab. 8:
Event list with error and information messages
ID
Event name
Event description Measure
ID57
OverTemp-
The temperature
Fault_Inv
of the inverter is
too high.
ID58
OverTemp-
The boost temp is
Fault_Boost
too high.
ID59
OverTemp-
The ambient tem-
Fault_Env
perature is too
high.
ID60
PE Connect
Connection error
Fault
PE conductor.
ID61-
(Reserved)
ID64
REFUsol 50K-3T
982081 | 03 | 2021-03
Check that the inverter has been assembled and installed according to the specifica-
tions in this manual.
Check the solar radiation conditions and the ambient temperature at the inverter.
Check the proper function of the cooler (dirt) and the function of the fans.
Check secure contacting of the PE conductor.
Error Messages and Troubleshooting