Event list with error and information messages
Tab. 8:
ID
Event name
Event description Measure
ID65
Unrecover-
AC current is too
HwAcOCP
high, hardware er-
ror cannot be re-
set.
ID66
Unrecover-
DC bus voltage, an
BusOVP
error cannot be
reset.
ID67
UnrecoverIa-
AC current is too
cRmsUnbal-
high, a fault can-
ance
not be reset.
ID68
Unrecover-
DC current is
IpvUnbal-
asymmetrical, a
ance
fault cannot be re-
set.
ID69
Unrecov-
DC bus voltage is
erVbusUn-
unbalanced, an er-
balance
ror cannot be re-
set.
ID70
UrecoverO-
AC current is too
CPInstantDC
high, a fault can-
not be reset.
60
Error Messages and Troubleshooting
Main Menu (v2.6)
ID65-ID70 are internal faults of the inverter, switch off the DC switch, wait 5 minutes
and switch on the DC switch again. If no troubleshooting is possible, contact REFU
Service.