Hot tap
Vorschau ausblenden Andere Handbücher für t-mass I 300-digital:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EA01288D
12.8
Removing the measuring device
Precondition:
 The retractable assembly must be installed as described in Section 14.6 →  24.
WARNING
L
The measuring device is energized!
Risk of fatal injury from electric shock.
Open the measuring device only when the device is de-energized.
DANGER
L
If the sensor is exposed to the full process pressure, strong internal forces act on the
sensor. The sensor can accelerate to high speeds.
Risk of injury.
Therefore it must be ensured that the sensor is not able to accelerate to dangerously high
exit speeds. The following measures must be taken:
Make sure that the process pressure does not exceed 16 barg (232 psi)
Before you release the sensor coupling, make sure that the safety chain is properly hooked
into the hot tap and sensor fastening points and is taut.
CAUTION
L
Hot surfaces!
Burn hazard.
Before commencing work: allow the system and measuring device to cool down to a
touchable temperature.