Hot tap
Vorschau ausblenden Andere Handbücher für t-mass I 300-digital:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12.7
Lowering the sensor to the calculated insertion depth
1 →
p 16bar
<
(
< 232 psi)
Open the ball valve slowly (1),
open the coupling nut until some
gas escapes (2).
NOTICE
Risk of damage to the sensor tip!
Do not insert the sensor too far.
4
36 mm
Tighten the coupling nut by hand.
Mounting for the first time:
tighten coupling nut with 1 ¼
turns.
Repeat mounting: tighten
coupling nut with 1 turn.
NOTE!  If strong vibrations can
be expected, tighten the coupling
nut with 1½ turns when
mounting for the first time.
Endress+Hauser
2 →
2.
1.
1.
For t-mass 300: The sensor can
then be inserted into the tube.
Turn the hexagonal bolt
counterclockwise (1) and
introduce the sensor to the
calculated insertion depth (2).
19 mm
230
9
220
2.
210
8
200
190
180
7
3
1.
19 mm
2.
For t-mass 500-digital: The
sensor can then be inserted into
the tube. Turn the hexagonal bolt
counterclockwise (1) and
introduce the sensor to the
calculated insertion depth (2).
EA01288D
230
9
220
210
8
200
190
180
7
27