2.5 - ADJUSTING CURRENT LIMITER
The charging station has current limiter (rotary switch) on the mainboard which is shown in
figure11. This switch is used for adjusting the current and power of charging station. The arrow in
the middle of the rotary switch must be adjusted gently by rotating with a flathead screwdriver to
the position of the required current rate. The details of the current rates are desicribed in table 7.
Current
Limiter
Position
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
IG v7.3.0 2021
Current Limit Value
Phase
22 kW
11kW
6 A
6 A
10 A
10 A
16 A
16 A
1-
20 A
Phase
25 A
30 A
32 A
6 A
6 A
10 A
10 A
16 A
16 A
3-
20 A
Phase
25 A
30 A
32 A
Table-7
© 2021 Vestel - All rights reserved
Figure-11
Required Circuit Braker on AC Mains
EV Charging Station Current
Limiter Setting
10 A
13 A
16 A
20 A
25 A
30 A
32 A
SW2
C-Curve MCB
Table-8
13 A
16 A
20 A
25 A
32 A
40 A
40 A
English - 20