2.5 - ADJUSTING CURRENT LIMITER

The arrow in the middle of the rotary switch must be adjusted by gently rotating with a flathead
screwdriver (Tip width 2.00-2.5 mm)to the position of the required current rate. The device current
limiter is set to 16A in production by default.
Current Limiter
Position
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
IG v7.3.0 2021
Current Limit
Phase
22 kW
10 A
13 A
16 A
1 Phase
20 A
25 A
30 A
32 A
10 A
13 A
16 A
3 Phase
20 A
25 A
30 A
32 A
Table-7
© 2021 Vestel - All rights reserved
Figure-11
Required Circuit Braker on AC Mains
11kW
EV Charging Station Current
Limiter Setting
10 A
13 A
16 A
10 A
13 A
16 A
SW2
10 A
13 A
16 A
20 A
25 A
30 A
32 A
Table-8
C-Curve MCB
13 A
16 A
20 A
25 A
32 A
40 A
40 A