Herunterladen Inhalt Inhalt Diese Seite drucken

Dimensions And Weight; Operating Instructions; Water Temperature; Maximum Pressure And Flow Rate - Interpump Group SS70 Betriebs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für SS70:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 56
6

DIMENSIONS AND WEIGHT

For Standard Version pump dimensions and weight, refer to Fig. 2.
Dry weight 43 kg.
7

OPERATING INSTRUCTIONS

SS70 pumps have been designed to operate with
filtered water (see par. 9.7) and at a maximum
temperature of 85 °C, with the head and all the
components in contact with the fluid made of AISI 316L
plus special high and low pressure energized seals.
SN70 pumps have been designed to operate with
filtered water (see par. 9.7) and at a maximum
temperature of 85 °C, with the head made of
AISI 420 and all the components in contact with the
fluid made of AISI 316L plus special high and low
pressure energized seals.
SW70 pumps have been designed to operate with
filtered sea water (see par. 9.7) and at a maximum
temperature of 85 °C, with the head and all the
components in contact with the fluid made of
AISI 316L plus special high and low pressure
energized seals.
Other liquids can be used only upon approval by the
Technical or Customer Service Departments.
7.1

Water temperature

The permissible water temperature is 40 °C.
However, the pump can be used with water up to a
temperature of 85 °C.
In this case, it is best to consult the Technical or
Customer Service Department.
7.2

Maximum pressure and flow rate

The rated specifications stated in our catalog are the max.
that can be obtained by the pump. Independently of the
power used, the maximum pressure and rpm indicated in
the specification label can never be exceeded unless upon
prior authorisation by our Technical or Customer Service
Departments.
7.3

Minimum operating speed

The minimum rotating speed of the pump is 200 rpm, any
lower minimum speed must be expressly authorized by our
Technical or Customer Service Departments.
7.4

Sound emission

The sound pressure detection test was performed according
to Directive 2000/14 of the European Parliament and Council
(Machinery Directive) and EN-ISO 3744-2010 with class 1
instrumentation.
A final detection of sound pressure must be performed on the
complete machine/system.
Should the operator be located at a distance of less than
1 meter, he will have to use appropriate hearing protection
according to current regulations.
7.5

Vibration

The detection of this value shall be carried out only with the
pump set up on the plant and at the performance declared by
the customer. Values must be in accordance with regulations.
7.6

Brands and types of oils recommended

The pump is supplied with oil suitable for room temperatures
from 0 °C to 30 °C.
Some types of recommended oil are indicated in the table
below, these oils have additives to increase corrosion
resistance and fatigue resistance (DIN 51517 part 2).
Alternatively you can also use Automotive Gear SAE 85W-90
oil for gearing lubrication.
Manufacturer
Lubricant
AGIP ACER220
Aral Degol BG 220
BP Energol HLP 220
CASTROL HYSPIN VG 220
CASTROL MAGNA 220
Falcon CL220
ELF POLYTELIS 220
REDUCTELF SP 220
NUTO 220
TERESSO 220
FINA CIRKAN 220
23
Fig. 2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis