Product
presentation
Malfunction
Steam release when drawing off
Control panel failure or display problem
After any maintenance or repair work, check the proper operation of the water heater.
4.4.

Ohmic values of the sensors according to the temperature

5.
Customer Service
Use only original spare parts from the manufacturer. Any work on electrical parts must be carried
out by a specialist.
When ordering from a brand distributor, specify the exact type of water heater and its serial number indicated on the
rating above the hot water outlet. plate located The address of the customer service is indicated on the back cover.
62
Installation
Possible cause
The electric booster pump is
continuously powered
No power
Malfunction of the panel.
----- Immersion sleeve sensor, evaporator sensors, air intake sensor
Temperature [°C]
Maintenance,
Settings /
Servicing and
Operation
Troubleshooting
Warranty
Diagnosis and troubleshooting
Turn off the power supply and notify
the installer.
Check power supply.
Replace the panel.