Description of the modes
The product performance is optimized for a continuous power supply operation.
Mode
3.1.
Manual mode operation
This operating mode allows the adjustment of the DHW temperature from 50°C to 62°C. This mode will optimize the
production of domestic hot water according to the consumption. To do this, the electric booster pump can be used.
In the case of a Peak hours/Off-peak hours connection, choose a higher set point for more comfort.
Set point temperature: 56°C
3.2.
ECO mode operation
With this mode, the water heater will favor the operation using the heat pump. This mode optimizes the energy
consumption using an ideal set point temperature (54°C) which offers the best efficiency.
This mode is particularly recommended in the case of a continuous power supply.
Depending on the installation conditions (continuous or Peak hours/Off-peak hours) and the room temperature, this
mode may use the electric booster pump.
54
Installation
Used to adjust domestic hot water set point temperature to adapt it to
the needs.
Operation at a reduced set point temperature (54° C)
Extended absence : freeze protection of the water heater (15°C)
Minimum set point temperature: 50°C
Maintenance,
Settings /
Servicing and
Operation
Troubleshooting
Description
Warranty
Maximum set point temperature: 62°C