Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance, Servicing And Troubleshooting; Advices To The User; Maintenance - Atlantic EGEO Betriebs Und Installationsanleitung

Brauchwasser-wärmepumpe - standmodell
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 102
Product
presentation
1.

Advices to the user

The water heater must be drained when the absence mode cannot be used or when the appliance is turned off.
Proceed as follows:
I.
Turn off the power supply.
III.
Open a hot water faucet.
2.

Maintenance

In order to maintain the performance of your water heater, it is recommended to perform regular maintenance.
:
By the USER
What
Security unit
General condition
The appliance must be turned off before opening the front cover and the top cover.
Par the PROFESSIONAL
What
The drainage of
condensate
Electrical connections
Electric booster pump
Scaling
56
Installation

Maintenance, servicing and troubleshooting

When
Once or twice a month
Monthly
:
When
Annually
Annually
Annually
Every 2 years
Maintenance,
Settings /
Servicing and
Operation
Troubleshooting
II.
Close the cold water supply.
IV.
Open the drain valve of the
safety unit.
How
Operate the pressure relief valve.
Check for proper flow of water
Check the general condition of your appliance:
no Error code , no leaks at the level of the water
connections...
How
Check if the condensate drain is clean.
Check the wires on internal and external wiring to make sure
they are not loose and all connectors are in place.
Check the proper functioning of the electric booster pump
through a power measurement.
If the water supplied to the water heater contains water
scales, descaling is required.
Warranty
.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis