V. Place the unit in a location with easy access.
VI. Report to figures in chapter « Installation ».
VII. This appliance is not designed to be installed above 2,000m.
EN
Never block, cover or obstruct the air inlets and outlets of the unit.
A drain pan must imperatively be installed under the water heater
when it is set up in a false ceiling, an attic or above inhabited
premises. A drain connection to the wastewater drain is required.
The water heater must be secured to the floor using the mounting
bracket provided for this purpose (in accordance with article 20
of EN 60335-1 standard).

HYDRAULIC CONNECTION

A new 3/4" (20/27) and 0.7 Mpa (7 bar) safety unit (or other pressure
relief device) ptotected from freezing must be installed on the inlet of
the water heater which will comply with local standards. A pressure
reducing equipment (not supplied) is required when the water supply
pressure is greater than 0.5 MPa (5 bar) which will be placed on the
main water supply.
Connect the safety unit to a discharge pipe, kept in the open air, in a
frost-free environment, continuously sloping downwards to drain off
the heat-expanded water or to allow for drainage of the water heater.
No water accessory (shut-off valve, pressure reducing device, hose,
etc.) must be installed between the safety unit and the cold water
inlet of the water heater.
Do not connect the hot water connection directly to copper pipes.
It must be equipped with a dielectric connection (supplied with
the appliance). In case of corrosion of the hot water connection
threads not equipped with this protection, our warranty will not apply.
35