Dokument 3BA00156 Rev. 4 • 1.03.007
7. Error diagnosis and
Remedy
Other Errors
Other errors may also occur, indicating possible
defects in the soldering tool. These errors are:
The station permanently displays only
the room temperature. In this case,
there is a defect in the heating element
or cable with thermocouple‑controlled
soldering irons (i‑Tool, Power tool and
Tech tool).
The station permanently displays an
actual temperature that is too high. This
error can occur during operation of Chip
tool. In this case, switch off the station
and replace the soldering tool with an
intact one.
The display is switched off and no
longer displays anything, but the mains
switch continues to be illuminated. In
this case, the soldering station is over‑
loaded. Once the soldering station has
cooled down sufficiently (approx. 30
minutes), work can be continued.
i‑CON / 48
Fehlerbehandlung
Sonstige Fehler
Es können noch weitere Fehler auftreten, die
auf mögliche Defekte des Lötwerkzeuges hin‑
weisen. Diese sind:
Die Station zeigt permanent nur die
Raumtemperatur an. In diesem Fall
liegt bei den thermoelementgeregelten
Lötkolben (i‑Tool, Power Tool und Tech
Tool) ein Defekt am Heizkörper oder in
der Zuleitung vor.
Die Station zeigt permanent eine zu
hohe Ist‑Temperatur an. Dieser Fehler
kann beim Betrieb eines Chip Tools auf‑
treten. Schalten Sie in diesem Falle die
Station aus und ersetzen Sie das Löt‑
werkzeug gegen ein intaktes.
Das Display wird abgeschaltet und zeigt
nichts mehr an, der Netzschalter leuch‑
tet jedoch weiter. In diesem Fall liegt
eine Überlastung der Lötstation vor.
Ist die Lötstation ausreichend abge‑
kühlt (ungefähr 30 Minuten) kann weiter
gearbeitet werden.