Highlight the Critical array and press [Enter]. The following screen will then
appear:
Fastbuild™ Utility 1.xx (c) 1995-99 Promise Technology, Inc.
Array No.
Array 2
Stripe Block: Not available
Channel: ID
1 : Slave
[ ] Up [ ] Down [ESC] Exit [ENTER] Select [Space] Change Boot Drive
Under [Select Drive for Rebuild], highlight the drive to replace the failed drive.
Press enter and confirm that the data will be copied onto the selected drive. All
data on the replacement drive will be written over with mirrored information
from the array drive.
NOTE: For automatic rebuilds of a mirrored array, attach an extra
"spare" drive to the FastTrak66. Drives that are not assigned to an array
and are the same size or larger than the original will be used for the auto-
matic rebuild. This is performed in the background under all supported
operating systems, except DOS. At a later time, the failed drive can be
physically removed.