Manual EN
05-08-1999 11:30
Chapter 4
FastBuild™ Configuration Setup
The FastBuildTM setup gives menu choices to create and manage disk arrays
on the Promise FastTrak66 adapter.
FastTrak (tm) / FastTrak66 (tm) BIOS Version 1.xx (Build xxxx)
(c) 1995-99 Promise Technology, Inc. All Rights Reserved
ID
MODE
1*
2+0 Stripe
2
1x2 Mirror
Press <Ctrl-F> to enter Fastbuild (tm) Utility
BIOS Startup Screen
During the system startup, the Promise BIOS screen will appear as shown
above.This displays the adapter BIOS version and array status. The array sta-
tus consists of three possible conditions: Functional, Critical, Offline.
Functional - The array is operational.
Critical - A mirrored array contains a drive that has failed or disconnected.
The remaining drive member in the array is functional. However, the array has
temporarily lost its ability to provide fault tolerance. The user should identify
the failed drive though the FastBuildTM Setup menu utility, and then replace
the problem drive.
Offline - A mirrored array has 2+ drives or a striped array has 1+ drives that
have failed or have been disconnected. When the array condition is "offline," the
user must replace the failed drive(s), then restore data from a backup source.
FastBuildª Setup Menu Navigation
When using the menus, these are some the basic navigation tips: Arrow keys
highlights through choices; [Space] bar key allows to cycle through options;
[Enter] key selects an option; [ESC] key is used to abort or exit the current
menu.
Pagina 17
SIZE
TRACK-MAPPING
13044M
611/128/32
6522M
620/32/63
17
STATUS
Functional
Functional