8. Setting the jumpers at the
slave

8 Setting the jumpers at the slave

Jumper B1
Jumper B2
Jumper B3

9 Technical specifications

VdS approval
numbers
28 / 108
Jumper connects B1.b and B1.c: Activation slave
beeps after activation release (acknowledgement
of activation request by activation master)
Jumper connects B1.b and B1.a: Activation slave
beeps when burglar alarm system pulls pin 29 on
the activation master to ground (VdS-compliant:
Acknowledgement of activation by burglar alarm
system)
If jumper B2 is inserted, the range of the internal
antenna is maximised. The range of the optional
external antenna remains unchanged.
You limit the range of the external antenna with an
aluminium sleeve. In this case, set the jumper.
Using the external antenna without an aluminium
sleeve is not VdS-compliant. The manual provides
more information.
Do not plug in jumper B3.
Activation unit - G101160 - Class C
Deactivation unit - G101161 - Class C
Block lock function - G102014 - Class C
Block lock Activation slave