TROUBLESHOOTING

Fault
Engine will not start
Engine is running loudly/irregularly
No electrical output
Engine will not switch off
Repairs
Only use manufacturer's recommended accessories and replacement parts. If the unit should fail despite our
quality controls and your maintenance, only allow an authorised electrician to carry out repairs.
106
Cause
No fuel in the tank.
Fuel valve closed.
Air filter dirty.
Engine switch is set to "OFF".
Recoil starter defective.
No engine oil.
Spark plug dirty.
Engine oil level too low (oil warning
lamp is flashing).
On/off switch for motor operation
set incorrectly.
Spark plug dirty
Air filter severely dirty
Fuel contaminated/stale
Choke lever set to "CHOKE"
Incorrect fuel - diesel instead of
petrol
Fault in the a.c. power generator
Ignition switch-off wire defective
Remedy
Fill the tank up.
Open the fuel valve.
Clean the air filter.
Set the engine switch to "ON".
Repair the recoil starter.
Refill the engine oil.
Clean the spark plug
Refill the engine oil.
Set to the correct position
Clean/replace the spark plug.
Clean/replace the air filter.
Drain and replace the fuel.
Set the choke lever to "RUN"
Drain the fuel and fill with the cor-
rect fuel
For service under warranty, inform
your representative
Close the fuel valve and wait until
the engine shuts off; call customer
service